|










|
STYLE BE
Insulator Type Thermocouples
|

|
ORDER SYMBOL |
WIRE GAUGE |
MAXIMUM INSULATOR OD |
AVAILABLE CALIBRATION TYPES |
| SINGLE ELEMENT |
DUAL ELEMENT |
BE20
BE16 BE14 BE8
|
20
16 14 8
|
.220"
.260" .312" .445"
|
.220"
.312"
.312" .645"
|
E, J, K & T
E, J & K E, J, K & T E, J & K
|
|
To Order: Complete the part number by inserting a single letter calibration symbol for single element or a double letter calibration symbol for dual element and indicate the "L" length in inches.
EXAMPLES: BE14K - 18, Type K, single element, L = 18". BE14KK - 18, Type K, dual element, L = 18".
|
PLATINUM INSULATOR TYPE THERMOCOUPLE ELEMENTS Platinum insulator type thermocouple elements are available with either Mullite or high purity Alumina insulators. To minimize the possibility of silica contamination. Alumina insulators are recommended for temperatures above 2400ºF (1316ºC). In either case a single one-piece insulator is used on elements 36 inches or less in length. The use of a one-peice insulator provides optimum support and protection for the delicate platinum conductors. As a standard feature platinum elements are terminated with copper sleeves. Copper sleeves provide a convenient, durable means of connecting platinum elements to a connector block without damaging the soft platinum conductor wires.
|
|